UF Membrane Module 8 inch PVC Ultrafiltration Membrane Module UFc200AM Drinking Water Treatment
Product Overview
UFc200AM capillary hollow fiber membrane is high polymer material, which will not have any phase change. Modified PVC material, which is adopted on this product, has good permeable rate, good mechanical properties, good chemical resistance and pollution resistance. MWCO is 100K Dalton, membrane ID/OD is 1.0mm/1.8mm, filtering type is inside-out.
Applications
- Production of mineral water, mountain spring water and other sterile liquid.
- Drinking treatment of tap water, surface water, well water, river water, etc.
- Pretreatment of RO.
- Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service conditions of different water sources:
Ingredient | Effect |
SS, Particles?> 1μm | Removal Rate?≥ 99% |
SDI | ≤ 3 |
Bacteria, Viruses | >?4 log |
Turbidity | < 0.1NTU |
TOC | Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU.
Product Parameters
Technical Parameters:
Filtering?Type | inside-out |
Membrane?Material | Modified?PVC |
MWCO | 100K Dalton |
Membrane?Area | 27m2 |
Membrane?ID/OD | 1.0mm/1.8mm |
Dimensions | Φ200mm*1480mm |
Connector?Size | DN40?Union |
Application Data:
Pure?Water?Flux | 7,000L/H?(0.15MPa, 25℃) |
Designed?Flux | 35-100L/m2.hr?(0.15MPa, 25℃) |
Suggested?Working?Pressure | ≤ 0.2MPa |
Maximum?Transmembrane?Pressure | 0.2MPa |
Maximum?Working?Temperature | 45℃ |
PH?Range | Working: 4-10; Washing: 2-12 |
Operating?Mode | Cross-flow?or?Dead-end |
Feeding Water Requirements:
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity | ≤ 15NTU |
Oil?&?Grease | ≤?2mg/L |
SS | ≤ 20mg/L |
Total?Iron | ≤?1mg/L |
Continuous?Residual?Chlorine | ≤?5ppm |
COD | Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters:
Maximum?Backwashing?Pressure | 0.2MPa |
Backwashing?Flow?Rate | 100-150L/m2.hr |
Backwashing?Frequency | Every?30-60min. |
Backwashing?Duration | 30-60s |
CEB?Frequency | 0-4?times per day |
CEB?Duration | 5-10min. |
CIP?Frequency | Every 1-3 months |
Washing?Chemicals: | |
Sterilization | 15ppm Sodium Hypochlorite |
Organic?Pollution?Washing | 0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing | 1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material:
Component | Material |
Membrane | Modified?PVC |
Sealing | Epoxy?Resins |
Housing | UPVC |