Based on domestic market and expand abroad business is our enhancement strategy for Uf Membrane Filter , Ro Water Filter Membrane , Drinking Filter , Base within the small business concept of high quality initially, we want to fulfill more and additional friends within the word and we hope provide the ideal solution and services to you.
Fixed Competitive Price Submerged Bioreactor - UF Membrane Module PVC Ultrafiltration Membrane Module UFc8040 RO housing – Bangmo Detail:
Applications
Production of mineral water, spring water, or other sterile liquid.
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
Ingredient |
Effect |
SS, Particles?> 1μm |
Removal Rate?≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
>?4 log |
Turbidity |
<0. 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU. This product is qualified for drinking water related products.
Product Parameters
Technical Parameters
Filtering?Type |
Inside-out |
Membrane?Material |
Modified?PVC |
MWCO |
100K Dalton |
Membrane?Area |
19m2 |
Membrane?ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ200mm*1016mm |
Connector?Size |
Φ29mm |
Application Data
Pure?Water?Flux |
5,000L/H?(0.15MPa, 25C) |
Designed?Flux |
35-100L/m2.hr?(0.15MPa, 25C) |
Suggested?Working?Pressure |
≤ 0.2MPa |
Maximum?Transmembrane?Pressure |
0.2MPa |
Maximum?Working?Temperature |
45C |
PH?Range |
Working: 4-10; Washing: 2-12 |
Operating?Mode |
Cross-flow?or?Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil?&?Grease |
≤?2mg/L |
SS |
≤ 20mg/L |
Total?Iron |
≤?1mg/L |
Continuous?Residual?Chlorine |
≤?5ppm |
COD |
Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum?Backwashing?Pressure |
0.2MPa |
Backwashing?Flow?Rate |
100-150L/m2.hr |
Backwashing?Frequency |
Every?30-60min. |
Backwashing?Duration |
30-60s |
CEB?Frequency |
0-4 times per day |
CEB?Duration |
5-10min. |
CIP?Frequency |
Every 1-3 months |
Washing?Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic?Pollution?Washing |
0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing |
1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
Component |
Material |
Membrane |
Modified?PVC |
Sealing |
Epoxy?Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
Bear Customer 1st, Good quality first in mind, we work closely with our prospects and supply them with efficient and professional services for Fixed Competitive Price Submerged Bioreactor - UF Membrane Module PVC Ultrafiltration Membrane Module UFc8040 RO housing – Bangmo , The product will supply to all over the world, such as: Slovak Republic, Rwanda, Gambia, We taking advantage of experience workmanship, scientific administration and advanced equipment, ensure the product quality of production, we not only win the customers' faith, but also build up our brand. Today, our team is committed to innovation, and enlightenment and fusion with constant practice and outstanding wisdom and philosophy, we cater to the market demand for high-end products, to do professional products.