Reliable good quality and very good credit standing are our principles, which will help us at a good -ranking position. Adhering to your tenet of quality 1st, purchaser supreme for Anaerobic Mbr , Membrane Technology , Ultrafiltration Process , We are always looking forward to forming successful business relationships with new clients around the world.
Factory Supply Stainless Steel Water Filter - UF Membrane Module PVC Ultrafiltration Membrane Module UFc8040 RO housing – Bangmo Detail:
Applications
Production of mineral water, spring water, or other sterile liquid.
Drinking treatment of tap water, surface water, well water and river water.
Pretreatment of RO.
Treatment, recycle and reuse of industrial waste water.
Filtration Performance
This product is proven to have below filtering effects according to the service?conditions of different water sources:
Ingredient |
Effect |
SS, Particles?> 1μm |
Removal Rate?≥ 99% |
SDI |
≤ 3 |
Bacteria, Viruses |
>?4 log |
Turbidity |
<0. 1NTU |
TOC |
Removal Rate: 0-25% |
*Above data is obtained under the condition that feeding water turbidity is < 15NTU. This product is qualified for drinking water related products.
Product Parameters
Technical Parameters
Filtering?Type |
Inside-out |
Membrane?Material |
Modified?PVC |
MWCO |
100K Dalton |
Membrane?Area |
19m2 |
Membrane?ID/OD |
1.0mm/1.8mm |
Dimensions |
Φ200mm*1016mm |
Connector?Size |
Φ29mm |
Application Data
Pure?Water?Flux |
5,000L/H?(0.15MPa, 25C) |
Designed?Flux |
35-100L/m2.hr?(0.15MPa, 25C) |
Suggested?Working?Pressure |
≤ 0.2MPa |
Maximum?Transmembrane?Pressure |
0.2MPa |
Maximum?Working?Temperature |
45C |
PH?Range |
Working: 4-10; Washing: 2-12 |
Operating?Mode |
Cross-flow?or?Dead-end |
Feeding Water Requirements
Before feeding water, a security filter < 50 μm should be set to prevent blockage caused?by large particles in raw water.
Turbidity |
≤ 15NTU |
Oil?&?Grease |
≤?2mg/L |
SS |
≤ 20mg/L |
Total?Iron |
≤?1mg/L |
Continuous?Residual?Chlorine |
≤?5ppm |
COD |
Suggested?≤ 500mg/L |
*Material of UF membrane is polymer organic plastic, there must not be any organic solvents in raw water.
Operating Parameters
Maximum?Backwashing?Pressure |
0.2MPa |
Backwashing?Flow?Rate |
100-150L/m2.hr |
Backwashing?Frequency |
Every?30-60min. |
Backwashing?Duration |
30-60s |
CEB?Frequency |
0-4 times per day |
CEB?Duration |
5-10min. |
CIP?Frequency |
Every 1-3 months |
Washing?Chemicals: |
Sterilization |
15ppm Sodium Hypochlorite |
Organic?Pollution?Washing |
0.2%?Sodium Hypochlorite + 0.1% Sodium Hydroxide |
Inorganic?Pollution?Washing |
1-2% Citric?Acid/0.2% Hydrochloric?Acid |
Component Material
Component |
Material |
Membrane |
Modified?PVC |
Sealing |
Epoxy?Resins |
Housing |
UPVC |
Product detail pictures:
Related Product Guide:
We emphasize development and introduce new products into the market every year for Factory Supply Stainless Steel Water Filter - UF Membrane Module PVC Ultrafiltration Membrane Module UFc8040 RO housing – Bangmo , The product will supply to all over the world, such as: Johor, Stuttgart, Liberia, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers,and establish a long term win-win business relationship. For more information,please contact us. And it's our great pleasure if you like to have a personally meeting in our office.